磁助式电接点开关也就是电源开关,整个电源回路的开断是通过内部的机械结构达到预先设定的限值时触发电接点开关。
Magnetic snap-action contact is also auxiliary power switch. The entire power circuit is disconnected or connected by activating the contact when the preset limit value is reached through internal mechanical mechanism.
订货说明
Order instructions
型号/数量/量程/开关动作点/接口尺寸/其它特殊事项
Model/quantity/measuring range/switch action point/interface dimensions/other special issues
投诉/更换/修理
Complaint/replacement/repair
售后服务时请给出生产编号和产品型号,生产编号印在表盘上,产品型号印在标牌上。
At customer service, please provide with the production number and product model. The production number is printed on the dial, while the product model is printed on the nameplate.
SF6-气体密度继电器/远传密度继电器必须长时间恒温才能达到温度补偿作用(至少两小时) 。
偿作用(至少两小时) 。
SF6- gas density monitor/ remote gas density monitor must be kept in constant temperature for a long time (at least two hours) so as to achieve temperature compensation.
只有厂家可以进行维修,不允许开仪表,否则会使显示和开关点产生误差。
No one other than the manufacturer is allowed to disassemble the instrument for fear that any error may occur to the display and switch point.
B.电气接口
Electrical interface
接线必须由经过培训的人员操作 .接线分布和开关功能都在仪表型号牌上给出,并注明了接线柱和接地柱.规定供电电线必须考虑仪表的大电流需求量并符合 IEC227 或 IEC245 标准.
The wirings shall be performed by professionally trained personnel. Wiring distribution and switching functions are displayed on the instrument type plate with terminal binding posts and ground pole also indicated. The specifications of power line must allow for the maximum current requirement of the instrument and comply with IEC227 or IEC245.
使用和维护
Use and maintenance
密度继电器/远传密度继电器应垂直安装,用在室外的密度继电器/远传密度继电器应避免阳光直射到仪表上,好在仪表上加装防护罩。
Gas density monitor/remote gas density monitor shall be installed upright. For a gas density monitor used outdoors, direct exposure to sunlight is not allowed, and it is advisable to use a shield.
密度继电器/远传密度继电器安装部位应能较真实地反映设备内气体的温度。
Gas density monitor/remote gas density monitor shall be erected at a proper position to reflect the temperature of gas in relevant equipment.
用肥皂水浸湿的擦布清洁仪表,要清洁接线盒或插头时要先把电源断开,再接通电源前确保所有部件不潮湿。
Clean the instrument with a wiping cloth soaked in soap water. Cut off the power supply before cleaning the terminal box or plugs. Make sure that all components are dry before turning on the power again.
我们公司始终本着诚信经营的原则,以“以诚为本,以质取信”为宗旨,坚持“开拓、务实、守信”的企业精神,以诚挚的心,全方面的服务,为每一个客户创造价值,让客户来的放心,用的舒心。与您携手共进。
http://zndq11132.cn.b2b168.com
欢迎来到陕西卓纳电气科技有限公司网站, 具体地址是陕西省西安市陕西省西安市国家民用航天产业基地飞天路588号北航科技园6号楼四单元三层航大企业服务中心C410,老板是范宏科。
主要经营联系电话:13060405606 陕西卓纳电气科技有限公司集开发,科研,生产,安装和服务为一体的**企业,主要从事SF6断路器,互感器,环网柜等高低压电气设备上的SF6密度继电器,SF6密度表,SF6密度继电器三通阀门等电力保护设备的专业生产厂家。。
单位注册资金单位注册资金人民币 100 - 250 万元。
我司供应:SF6密度继电器,SF6密度继电器三通阀门,SF6充气接头,SF6密度继电器防雨罩,SF6密度继电器厂家等产品,我们的产品质量优良,种类齐全,销售范围广,服务专业;如果您对我公司的产品有兴趣,请在线留言或者来电咨询。